Abstract:

This research aim to compare the firing of the same distance and the same angle control at three phase controlled rectifier with seen generated harmonic at input (AC side). Then calculate of rectifier efficiency and power factor comparison from both the control type. The rectifier use passive filter with resistance 11 ohm and is analysed with program simulation using PSPICE version 7.1. Result of research indicate that use of the same distance control generates the 5th and 7th harmonics, while the same angle control generates the 3rd , 5th and 7th harmonics at the input (AC side). At the output (DC side), the same distance control type generates the 6th voltage ripples, while the same angle control generates the 2nd, and 6th voltage ripples. The result of calculation of voltage ripples that happened equal to 3.5% with efficiency 99.8% at same distance control, while at the same angle control obtained voltage ripples equal to 4% with efficiency 99.7% . At the firing angle 300 obtained by THD input equal to 50.26% with power factor equal to 0.89 at same distance control type, while the same angle control obtained by THD input equal to 53,831% with power factor to 0,87. From this result indicate that the firing of thyristor with the same distance better then is the same angle control.

Keywords: control type, voltage ripples, efficiency, power factor
Published at: Vol 11, No 2 (2007) pages: 71-77
DOI:

Access Counter: 970 views, 684 PDF downloads, .

Full PDF Download

References:

Muhammad Rashid. Elektronika Daya, PT Prenhallindo, Jakarta, 1993.

Muhammad Rashid. SPICE for Power Electronics and Electric Power. Prentice-Hall International, 1993.

Arrillaga, D.A. Bradley and Bodger. Power System Harmonics Analyzer, John Wiley and Sons, 1985.

Prasad N. Enjeti, et.al. Analysis and Design of a New Active Power Filter to Cancel Neutral Current Harmonics in Three Phasa Four Wire Electric Distribution System. IEEE Transaction on Industry Application. (1994) Vol 30 No. 6.

Yahya Chusna Arif. Rancang Bangun DC Power Suplay Tiga Phasa dengan Harmonisa Rendah. Jurnal EEPIS, 2001.

O. Penangsang, Wibowo. RS. Analisis dan Simulasi Peningkatan Faktor Daya pada Sistem Kelistrikan yang Mengandung Harmonisa. Studi Kasus Sistem Kelistrikan Pabrik semen Tuban I, II, III. Lembaga Penelitian ITS, 2002.

Yahya Chusna Arif. Teknik Perbaikan Kualitas Daya pada Penyearah Terkontrol 3 Phasa dengan Menggunakan Sistem Simetri dan Injeksi harmonisa ketiga. IES, 2002.

A.B. Plunkett. A Current-Controlled PWM Transistor Inverter Drive. IEEE/IAS Annual Meeting Conference Record. 1979.

B.K.Bose. An Adaptive Hysterisis-Band Current Control Technique of a Voltage-Fed PWM Inverter for Machine Drive System, IEEE Transactions on Industrial Electronics. 1990.

David. M. Brod. Current Control of VSI-PWM Inverter. IEEE Transactions on Industry Applications. 1985.

Sudirman S, dkk. Analisis Perbandingan Kinerja Motor Arus Searah Dengan Menggunakan Sistem Kendali PWM dan Non-PWM. Proceeding International Seminar on Electrical Power, Electronics, Communication, Control and Informataics (EECCIS). Universitas Brawijaya Malang. 2006.

Sri Kurniati A. Analisis dan Simulasi Penyearah Tiga Phasa Terkendali Dengan Menggunakan Kombinasi Filter Pasif dan Aktif. Tesis Unhas. 2006.

Nasrun Haryanto. Analisis Kinerja Penyearah Tiga Phasa Terkendali Dengan Menggunakan PSPICE. Tesis ITB, 1999.

Sri Kurniati A, dan Sudirman S. Eliminasi Harmonik Pada Penyearah Terkendali Tiga Phasa Dengan Menggunakan Filter Hibrid. Media Exacta Volume 8 No.1 Januari 2007.